Smartd daemon reports disk failure below:
[root@asl43 ~]# WARNING: Your hard drive is failing Device: /dev/bus/0 [megaraid_disk_48], failed to read SMART values
Any model using LSI 2208 (MegaRAID 9266, 9271) or 3108 RAID chip
Using storecli64, disk_48 (DID) is identified as a global hot spare (GHS).:
# /opt/MegaRAID/storcli/storcli64 /c0 /eall /sall show Controller = 0 Status = Success Description = Show Drive Information Succeeded. Drive Information : ================= ---------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ---------------------------------------------------------------------------- 252:0 47 Onln 0 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:1 52 Onln 0 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:2 53 Onln 1 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:3 54 Onln 1 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:4 51 Onln 1 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:5 50 Onln 1 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:6 49 Onln 1 1.818 TB SAS HDD N N 512B ST2000NM0045 U - 252:7 48 GHS - 1.818 TB SAS HDD N N 512B ST2000NM0045 D -
SMART data cannot be retrieved on hot spare drive(s). Thus the warning message can be safely ignored.